0%

Relay dodokpɔ ƒe gbɔdɔɖowo

AMT205 dodokpɔwɔla

  • Ŋutete siwo ku ɖe ametakpɔnu siwo wotsɔna dzidzea nu kple dzidzenuwo dodokpɔ ŋu
  • Ŋutete be woado mita kple transducers ƒomevi ɖesiaɖe kpɔ
  • Ŋutete be woawɔ dodokpɔ siwo sɔ kple capacitor voltage transformer (VT/CVT) dodokpɔwo
  • Ŋutete be woawɔ current transformer (CT) dodokpɔwo
  • Ŋutete be woado ka ƒe tsitretsitsi kpɔ
  • RTD dodokpɔ ƒe ŋutete
  • Nudzralawo ƒe ŋkɔwo
  • Dodokpɔ ƒe ɖaseɖigbalẽwo
AMT205 dodokpɔwɔla
  • 6 × 32 A

    current outputs

  • 6 × 300 V

    voltage outputs

  • IEC 61850

    GOOSE · Sampled Values

Ŋutete siwo ku ɖe ametakpɔnu siwo wotsɔna dzidzea nu kple dzidzenuwo dodokpɔ ŋu

Protective relay and instrument test software, updated continuously and free of charge.

01Dodokpɔ le elektrikŋusẽ, static kple xexlẽdzesi relay ƒomevi ɖesiaɖe ŋu
02Kpekpeɖeŋu na Xrio kple Rio ƒe faɛlwo katã
03Dodokpɔ siwo nɔa anyi ɣeyiɣi kpui aɖe ko wɔwɔ
04Dodokpɔwo wɔwɔ tso Point to Point alo End to End
05GPS kple Wi-Fi module si wotu ɖe eme
06Wɔ dodokpɔwo le ɖokuiwò si
07Dodokpɔwo ŋuti nyatakaka siwo de to nana
08Dɔwɔƒe vovovowo ƒe nyatakakagbalẽvia yɔyɔ le wo ɖokui si
09Nusiwo sɔ kple Windows dɔwɔɖoɖo (XP, 7, 8, 10, 11) .
10Android dɔwɔɖoɖo ƒe kpekpeɖeŋu
11Auto Save Gbugbɔ wɔe eye nàɖee ɖa
12Farsigbe me mɔfiame le PDF ƒe nɔnɔme me
13Bootloader mɔ̃ɖaŋununya zazã atsɔ awɔ Firmware yeyee
14video siwo me nufiame le

What you can test with AMT

One test set for relays, instrument transformers, breakers and more.

t · µΩIEC 62271-100

Ŋutete be woawɔ key kple sectioner dodokpɔwo

Opening and closing times, micro-ohm contact resistance and the coil's minimum operating voltage.

  • Ʋuʋu kple nuwuwu ƒe ɣeyiɣi dzidzedze
  • Kadodo ƒe tsitretsitsi dzidzedze
  • Dɔwɔwɔ ƒe elektrikŋusẽ suetɔ kekeake si le ŋusẽ ƒe ʋuƒoa ŋu
kWhIEC 62053

Ŋutete be woado mita kple transducers ƒomevi ɖesiaɖe kpɔ

Calibrating meters and transducers from a precise source while counting their energy pulses.

  • Nusiwo sɔ pɛpɛpɛ ŋutɔ na dodokpɔ mita kple transducers ƒomevi ɖesiaɖe
  • Wotsɔ pulse counter module ɖo eŋu na ŋusẽ xexlẽ le eɖokui si
VT · CVTIEC 61869-3/5

Ŋutete be woawɔ dodokpɔ siwo sɔ kple capacitor voltage transformer (VT/CVT) dodokpɔwo

Ratio and polarity, winding resistance, short-circuit impedance and the saturation point.

  • Trɔtrɔ ƒe xexlẽme kple polarity dodokpɔ
  • Wiring ƒe tsitretsitsi dodokpɔ
  • Kpuie nutome ƒe mɔxexeɖedɔléle
  • Saturation point dzidzedze dodokpɔ
CTIEC 61869-2

Ŋutete be woawɔ current transformer (CT) dodokpɔwo

Excitation curve and knee point, ratio and phase error, burden and core demagnetising.

  • Saturation point dzidzedze dodokpɔ
  • Agba dzidzedze dodokpɔ le mɔa kple sisi mɔnu
  • Hysteresis ƒe ʋuʋudedi
  • Akɔntabubu le amplitude kple phase ƒe vodada ŋu
  • Nu veviwo ƒe demagnetization
  • Evelia tsitretsitsi dzidzedze dodokpɔ kple fifia kple elektrikŋusẽ mɔnu
  • Trɔtrɔ ƒe xexlẽme dodokpɔ (kple voltage mɔnu, kple fifia mɔnu vaseɖe 128 amp fifia)
Pt100IEC 60751

RTD dodokpɔ ƒe ŋutete

Simulating RTD temperature sensors to test thermal relays and transducers.

Yd11IEC 60076

Ŋutete be woawɔ ŋusẽ ƒe tɔtrɔ ƒe dodokpɔwo

Ratio and vector group, no-load current, leakage reactance, tap changer and DC winding resistance.

  • Trɔtrɔ ƒe xexlẽme kple ƒuƒoƒo dodokpɔ
  • No-agba fifia dzidzedze dodokpɔ
  • Flux mama dodokpɔ
  • Nu veviwo ƒe demagnetization
  • Leakage reactance dodokpɔ
  • Tap changer ƒe yiyi dodokpɔ
  • DC ƒe tsitretsitsi dzidzedze dodokpɔ

Dodokpɔ ƒe ɖaseɖigbalẽwo

  • CE ƒe ɖaseɖigbalẽ
  • ISO 17025:2005 ƒe xexlẽdzesi