0%

Nā pūʻulu hōʻike relay

AMT205 hōʻike

  • Nā mana e pili ana i ka hoʻāʻo ʻana i nā relay pale a me nā lako ana
  • Hiki ke ho'āʻo i nā ʻano mika a me nā transducers
  • Hiki ke hana i nā ho'āʻo maʻamau a me ka capacitor voltage transformer (VT/CVT).
  • Hiki ke hana i nā ho'āʻo transformer o kēia manawa (CT).
  • Hiki ke ho'āʻo i ka pale pale
  • Hiki ke ho'āʻo RTD
  • Nā papa inoa o nā mea kūʻai aku
  • Nā palapala hōʻoia
AMT205 hōʻike
  • 6 × 32 A

    current outputs

  • 6 × 300 V

    voltage outputs

  • IEC 61850

    GOOSE · Sampled Values

Nā mana e pili ana i ka hoʻāʻo ʻana i nā relay pale a me nā lako ana

Protective relay and instrument test software, updated continuously and free of charge.

01ʻO ka hoʻāʻo ʻana i nā ʻano ʻano electromechanical, static a me nā relay helu
02Kākoʻo no nā faila Xrio a me Rio
03Ke hana nei i nā hoʻokolohua kūwaho
04Hana ʻana i nā hoʻāʻo ʻana i kahi kikoʻī a i ʻole End to End
05Loaʻa iā ia kahi module GPS a me Wi-Fi i kūkulu ʻia
06Hana ʻakomi i nā hoʻokolohua
07Hāʻawi i nā hōʻike piha o nā hoʻokolohua
08Hoʻopiha ʻakomi i ka palapala hōʻike o nā ʻoihana like ʻole
09Hoʻohālikelike me ka ʻōnaehana hana Windows (XP, 7, 8, 10, 11)
10Kākoʻo ʻōnaehana lawelawe Android
11E hoʻopaʻa hou a hoʻihoʻi
12Ke alakaʻi Farsi ma ka palapala PDF
13Ke hoʻohana nei i ka ʻenehana Bootloader e hoʻonui i ka Firmware
14wikiō hoʻonaʻauao

What you can test with AMT

One test set for relays, instrument transformers, breakers and more.

t · µΩIEC 62271-100

Hiki ke hana i nā ho'āʻo kī a me ka māhele

Opening and closing times, micro-ohm contact resistance and the coil's minimum operating voltage.

  • Ana o ka wehe a me ka pani manawa
  • Ana kū'ē pili
  • ʻO ke kaha liʻiliʻi loa o ka mana o ka uila
kWhIEC 62053

Hiki ke ho'āʻo i nā ʻano mika a me nā transducers

Calibrating meters and transducers from a precise source while counting their energy pulses.

  • ʻO ka pololei kiʻekiʻe no ka hoʻāʻo ʻana i nā ʻano mika a me nā transducers
  • Hoʻolako ʻia me kahi module counter pulse no ka heluhelu ʻana i ka ikehu ʻakomi
VT · CVTIEC 61869-3/5

Hiki ke hana i nā ho'āʻo maʻamau a me ka capacitor voltage transformer (VT/CVT).

Ratio and polarity, winding resistance, short-circuit impedance and the saturation point.

  • Lakiō hoʻololi a me ka ho'āʻo polarity
  • ʻO ka ho'āʻo kū'ēʻana i nā uwea
  • Impedance kaapuni pōkole
  • ʻO ka hoʻāʻo ʻana i ke ana kikoʻī
CTIEC 61869-2

Hiki ke hana i nā ho'āʻo transformer o kēia manawa (CT).

Excitation curve and knee point, ratio and phase error, burden and core demagnetising.

  • ʻO ka hoʻāʻo ʻana i ke ana kikoʻī
  • Ka ho'āʻo ana kaumaha o ke ala me ke ʻano kahe
  • ʻĀpana Hysteresis
  • Ka helu ʻana o ka amplitude a me ka hapa hapa
  • Ka demagnetization kumu
  • ʻO ka hoʻāʻo ʻana o ke ana kūʻē lua me ke ʻano o kēia manawa a me ke ala uila
  • ʻO ka hoʻāʻo lākiō hoʻololi (me ke ala uila, me ke ʻano o kēia manawa a hiki i ka 128 amp o kēia manawa)
Pt100IEC 60751

Hiki ke ho'āʻo RTD

Simulating RTD temperature sensors to test thermal relays and transducers.

Yd11IEC 60076

Hiki ke hana i nā ho'āʻo hoʻololi mana

Ratio and vector group, no-load current, leakage reactance, tap changer and DC winding resistance.

  • Lakiō hoʻololi a me ka ho'āʻo pūʻulu
  • ʻAʻohe hoʻouka ana ʻana o kēia manawa
  • ʻO ka hoʻāʻo hoʻokaʻawale ʻana
  • Ka demagnetization kumu
  • Ho'āʻo leakage reactance
  • ʻO ka hoʻāʻo hoʻomau paʻa hoʻololi
  • ʻO ka hoʻāʻo ana kūʻē DC

Nā palapala hōʻoia

  • palapala hōʻoia CE
  • ISO 17025:2005