0%

Rasys amddiffyn

ras gyfnewid AMB

  • Mewnbynnau cerrynt a foltedd yn ôl yr angen
  • Mewnbwn ac allbwn digidol yn ôl yr angen
  • Sgrin gyffwrdd fawr
  • porthladdoedd RS232 a RS485
  • Cefnogaeth ar gyfer protocol cyfathrebu IEC 61850
ras gyfnewid AMB
  • IEC 61850

    communication protocol

  • RS232 · RS485

    serial ports

  • Touch

    large touch screen

Swyddogaethau amddiffynnol

U<ANSI 27

Diogelu tan-foltedd

Trips when the voltage falls below the setting.

U>ANSI 59

Amddiffyniad gorfoltedd

Trips when the voltage rises above the setting.

I>> / I>ANSI 50/51

Amddiffyniad gorlif nad yw'n gyfeiriadol

Instantaneous (50) and IDMT time-delayed (51) tripping on overcurrent and short circuit.

IE>> / IE>ANSI 50N/51N

Amddiffyniad sylfaen nad yw'n gyfeiriadol

Instantaneous and time-delayed protection against residual current and phase-to-earth faults.

I> →ANSI 67

Amddiffyniad gorlif cyfeiriadol

Overcurrent that checks the power direction, operating only for forward or reverse faults.

IE> →ANSI 67N

Amddiffyniad Seiliau Cyfeiriadol

Directional earth fault, for ring networks and parallel feeders.

I2>ANSI 46

Cydran negyddol amddiffyn overcurrent

Detects unbalance, broken conductors and single phasing from the negative-sequence current.

θ>ANSI 49

Diogelu gorlwytho

A thermal model of the plant that trips before a cable, transformer or motor overheats.

CBFANSI 50BF

Diogelu methiant allweddol

Trips the upstream breakers when a breaker fails to open after a trip command.

I> ↑CLP

swyddogaeth canfod llwyth oer (CLP)

Raises the settings for a while after a long-dead feeder is re-energised, avoiding nuisance trips.

I2f / I1fInrush

Swyddogaeth canfod cyfredol Inrush

Recognises transformer inrush from the second harmonic and blocks false trips.

Id>ANSI 87

Amddiffyniad gwahaniaethol

Compares the currents into and out of the plant and clears faults inside the zone fast.

Nodweddion meddalwedd

01Mae ganddo amgylchedd meddalwedd pwerus a hawdd ei ddefnyddio ar gyfer sefydlu swyddogaethau amrywiol
02Y gallu i gofnodi hyd at 200 o osgilograffau, log taith
03Mae ganddo 4 grŵp rheoleiddio
04Modiwl meddalwedd Llwybro Signalau ar gyfer aseinio signalau swyddogaeth i drosglwyddo mewnbynnau ac allbynnau
05Y gallu i allbynnu gosodiadau cyfnewid ar fformat XRio

Tystysgrifau cyfnewid

  • Sefydliad Ymchwil Pŵer